{"id":1920,"date":"2022-04-28T09:32:16","date_gmt":"2022-04-28T07:32:16","guid":{"rendered":"https:\/\/www.fdi-access.com\/controle-acces\/ipassan-10-output-module\/"},"modified":"2023-03-14T10:23:24","modified_gmt":"2023-03-14T09:23:24","slug":"ipassan-10-output-module","status":"publish","type":"controle-acces","link":"https:\/\/www.fdi-access.com\/en\/acces-control\/ipassan-10-output-module\/","title":{"rendered":"IPassan 10-output module"},"content":{"rendered":"<div class=\"col-12 heading\">\n<h2 class=\"wp-block-heading\">Description<\/h2>\n<\/div><div class=\"col-12 paragraph\">\n<p>This module can manage 10 outputs and is connected to the iPassan central unit via the RS485 bus.<br\/>The maximum total capacity is 220 outputs by connecting up to 10 output modules.<br\/>Perfect for lift management !<\/p>\n<\/div><div class=\"col-12 heading\">\n<h2 class=\"wp-block-heading\">Key characteristics<\/h2>\n<\/div><div class=\"col-12 list\">\n<ul class=\"wp-block-list\">\n<li>10 relays capable of switching loads up to 5 amps.<\/li>\n\n\n\n<li>Can be easily complemented by the 12-output extension card.<\/li>\n\n\n\n<li>Perfect for controlling lifts, lighting, etc.<\/li>\n\n\n\n<li>LED indicators showing input status<\/li>\n\n\n\n<li>Secure RS485 communication<\/li>\n\n\n\n<li>Online and remote scalable firmware<\/li>\n\n\n\n<li>Designed for wall-mounting or for standard DIN Rail mounting<\/li>\n\n\n\n<li>Grey-coloured to recognize the product quickly in relation to the black iPassan base controllers<\/li>\n<\/ul>\n<\/div><div id=\"accordion_201056657\" class=\"row accordion_row\">\n            <div class=\"accordion col-12\">\n                                    <div class=\"accordion-item\">\n                        <div class=\"accordion-header\" id=\"heading_201056657_1\">\n                            <h3 class=\"accordion-button  collapsed \" type=\"button\" data-bs-toggle=\"collapse\" data-bs-target=\"#collapse_201056657_1\" aria-expanded=\"false\" aria-controls=\"collapse_201056657_1\">\n                                Power supply                            <\/h3>\n                        <\/div>\n                        <div id=\"collapse_201056657_1\" class=\"accordion-collapse collapse\" aria-labelledby=\"heading_201056657_1\">\n                            <div class=\"accordion-body\">\n                                <p>The 10-input module operates with a 12\/24 V AC\/DC power supply. When it is used inside the metal iPassan housing, it can share the same power supply as the controller.<\/p>\n                            <\/div>\n                        <\/div>\n                    <\/div>\n                                        <div class=\"accordion-item\">\n                        <div class=\"accordion-header\" id=\"heading_201056657_2\">\n                            <h3 class=\"accordion-button  collapsed \" type=\"button\" data-bs-toggle=\"collapse\" data-bs-target=\"#collapse_201056657_2\" aria-expanded=\"false\" aria-controls=\"collapse_201056657_2\">\n                                Connectivity and extension system                            <\/h3>\n                        <\/div>\n                        <div id=\"collapse_201056657_2\" class=\"accordion-collapse collapse\" aria-labelledby=\"heading_201056657_2\">\n                            <div class=\"accordion-body\">\n                                <p><!-- wp:paragraph --><\/p>\n<p>The iPassan-proposed input solution can be easily and cost-effectively extended and offers an additional advantage of:<\/p>\n<p><!-- \/wp:paragraph --> <!-- wp:list --><\/p>\n<ul>\n<li>10 outputs to use in any programmable output<\/li>\n<li>When complemented by the 12-output extension card, it can reach a total capacity of 22 outputs per module. 10 complete modules in the same RS485 row can control 220 outputs<\/li>\n<li>Additional devices easy to monitor, lifts, lighting, etc.<\/li>\n<li>1 12VDC 200mA output to power any additional devices<\/li>\n<li>The input module address is configured by entering the device number in the software<\/li>\n<\/ul>\n<p><!-- \/wp:list --><\/p>\n                            <\/div>\n                        <\/div>\n                    <\/div>\n                                        <div class=\"accordion-item\">\n                        <div class=\"accordion-header\" id=\"heading_201056657_3\">\n                            <h3 class=\"accordion-button  collapsed \" type=\"button\" data-bs-toggle=\"collapse\" data-bs-target=\"#collapse_201056657_3\" aria-expanded=\"false\" aria-controls=\"collapse_201056657_3\">\n                                Communication                            <\/h3>\n                        <\/div>\n                        <div id=\"collapse_201056657_3\" class=\"accordion-collapse collapse\" aria-labelledby=\"heading_201056657_3\">\n                            <div class=\"accordion-body\">\n                                <p>RS485 communication is used for communication with the control unit or interconnection with other I\/O modules<\/p>\n                            <\/div>\n                        <\/div>\n                    <\/div>\n                                        <div class=\"accordion-item\">\n                        <div class=\"accordion-header\" id=\"heading_201056657_4\">\n                            <h3 class=\"accordion-button  collapsed \" type=\"button\" data-bs-toggle=\"collapse\" data-bs-target=\"#collapse_201056657_4\" aria-expanded=\"false\" aria-controls=\"collapse_201056657_4\">\n                                Updating firmware                            <\/h3>\n                        <\/div>\n                        <div id=\"collapse_201056657_4\" class=\"accordion-collapse collapse\" aria-labelledby=\"heading_201056657_4\">\n                            <div class=\"accordion-body\">\n                                <p>The iPassan 10-output module firmware can be updated via the base controller using iPassan Manager software.<\/p>\n                            <\/div>\n                        <\/div>\n                    <\/div>\n                                <\/div>\n        <\/div>\n<div class=\"col-12 heading\">\n<h2 class=\"wp-block-heading\">Technical characteristics<\/h2>\n<\/div><div id=\"accordion_801996851\" class=\"row accordion_row\">\n            <div class=\"accordion col-12\">\n                                    <div class=\"accordion-item\">\n                        <div class=\"accordion-header\" id=\"heading_801996851_1\">\n                            <h3 class=\"accordion-button  collapsed \" type=\"button\" data-bs-toggle=\"collapse\" data-bs-target=\"#collapse_801996851_1\" aria-expanded=\"false\" aria-controls=\"collapse_801996851_1\">\n                                Power supply                            <\/h3>\n                        <\/div>\n                        <div id=\"collapse_801996851_1\" class=\"accordion-collapse collapse\" aria-labelledby=\"heading_801996851_1\">\n                            <div class=\"accordion-body\">\n                                <p>Operating voltage: 12\/24V AC\/DC<\/p>\n                            <\/div>\n                        <\/div>\n                    <\/div>\n                                        <div class=\"accordion-item\">\n                        <div class=\"accordion-header\" id=\"heading_801996851_2\">\n                            <h3 class=\"accordion-button  collapsed \" type=\"button\" data-bs-toggle=\"collapse\" data-bs-target=\"#collapse_801996851_2\" aria-expanded=\"false\" aria-controls=\"collapse_801996851_2\">\n                                Communication                            <\/h3>\n                        <\/div>\n                        <div id=\"collapse_801996851_2\" class=\"accordion-collapse collapse\" aria-labelledby=\"heading_801996851_2\">\n                            <div class=\"accordion-body\">\n                                <p>RS485: communication to the central unit or to other I\/O modules<\/p>\n                            <\/div>\n                        <\/div>\n                    <\/div>\n                                        <div class=\"accordion-item\">\n                        <div class=\"accordion-header\" id=\"heading_801996851_3\">\n                            <h3 class=\"accordion-button  collapsed \" type=\"button\" data-bs-toggle=\"collapse\" data-bs-target=\"#collapse_801996851_3\" aria-expanded=\"false\" aria-controls=\"collapse_801996851_3\">\n                                Outputs                            <\/h3>\n                        <\/div>\n                        <div id=\"collapse_801996851_3\" class=\"accordion-collapse collapse\" aria-labelledby=\"heading_801996851_3\">\n                            <div class=\"accordion-body\">\n                                <p>Outputs: 10 relays. 5A if 24VDC or 1A if 48VAC<\/p>\n                            <\/div>\n                        <\/div>\n                    <\/div>\n                                        <div class=\"accordion-item\">\n                        <div class=\"accordion-header\" id=\"heading_801996851_4\">\n                            <h3 class=\"accordion-button  collapsed \" type=\"button\" data-bs-toggle=\"collapse\" data-bs-target=\"#collapse_801996851_4\" aria-expanded=\"false\" aria-controls=\"collapse_801996851_4\">\n                                Temperature                            <\/h3>\n                        <\/div>\n                        <div id=\"collapse_801996851_4\" class=\"accordion-collapse collapse\" aria-labelledby=\"heading_801996851_4\">\n                            <div class=\"accordion-body\">\n                                <ul>\n<li>Operating: -20\u00b0C to 50\u00b0C<\/li>\n<li>Storage temperature: -20\u00b0C to 70\u00b0C<\/li>\n<li>Humidity : 85 RH max<\/li>\n<\/ul>\n                            <\/div>\n                        <\/div>\n                    <\/div>\n                                        <div class=\"accordion-item\">\n                        <div class=\"accordion-header\" id=\"heading_801996851_5\">\n                            <h3 class=\"accordion-button  collapsed \" type=\"button\" data-bs-toggle=\"collapse\" data-bs-target=\"#collapse_801996851_5\" aria-expanded=\"false\" aria-controls=\"collapse_801996851_5\">\n                                Size                            <\/h3>\n                        <\/div>\n                        <div id=\"collapse_801996851_5\" class=\"accordion-collapse collapse\" aria-labelledby=\"heading_801996851_5\">\n                            <div class=\"accordion-body\">\n                                <ul>\n<li>Size (L x l x H): 200 mm x 90 mm x 34 mm (210 mm x 145 mm x 65 mm with cover).<\/li>\n<li>Weight: 313g<\/li>\n<\/ul>\n                            <\/div>\n                        <\/div>\n                    <\/div>\n                                <\/div>\n        <\/div>\n","protected":false},"featured_media":2289,"template":"","categorie_produit":[77],"application":[104,105],"technologie":[79,80,81,82],"protocole":[98],"certification":[],"class_list":["post-1920","controle-acces","type-controle-acces","status-publish","has-post-thumbnail","hentry","categorie_produit-controllers","application-access-control-large-collective-housing","application-access-control-commercial-sites","technologie-mifare-plus-en","technologie-mifare-classic-en","technologie-desfire-en","technologie-ble-en","protocole-rs485-en"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.fdi-access.com\/en\/wp-json\/wp\/v2\/controle-acces\/1920","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fdi-access.com\/en\/wp-json\/wp\/v2\/controle-acces"}],"about":[{"href":"https:\/\/www.fdi-access.com\/en\/wp-json\/wp\/v2\/types\/controle-acces"}],"version-history":[{"count":0,"href":"https:\/\/www.fdi-access.com\/en\/wp-json\/wp\/v2\/controle-acces\/1920\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fdi-access.com\/en\/wp-json\/wp\/v2\/media\/2289"}],"wp:attachment":[{"href":"https:\/\/www.fdi-access.com\/en\/wp-json\/wp\/v2\/media?parent=1920"}],"wp:term":[{"taxonomy":"categorie_produit","embeddable":true,"href":"https:\/\/www.fdi-access.com\/en\/wp-json\/wp\/v2\/categorie_produit?post=1920"},{"taxonomy":"application","embeddable":true,"href":"https:\/\/www.fdi-access.com\/en\/wp-json\/wp\/v2\/application?post=1920"},{"taxonomy":"technologie","embeddable":true,"href":"https:\/\/www.fdi-access.com\/en\/wp-json\/wp\/v2\/technologie?post=1920"},{"taxonomy":"protocole","embeddable":true,"href":"https:\/\/www.fdi-access.com\/en\/wp-json\/wp\/v2\/protocole?post=1920"},{"taxonomy":"certification","embeddable":true,"href":"https:\/\/www.fdi-access.com\/en\/wp-json\/wp\/v2\/certification?post=1920"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}